Termite collars at slab stage in Oran Park NSW
Every pipe that passes through a slab leaves a gap around it, and that gap is a concealed route from the soil into the building. A termite collar closes it. Under AS 3660 it forms part of the termite management system for the house, and it has to be in place before the concrete goes down, because afterwards the penetration is sealed permanently around whatever is or is not there. We have recorded collars simply not installed on Oran Park pours, on separate penetrations, which is why they are now the first thing we look for at pre-pour here.
Fully licensed & accredited
-
NSW Fair Trading -
Australian Society of Building Consultants -
Strata Community Association -
Building Dispute Practitioners Society
A collar seals the gap around a pipe where it passes through the slab.
AS 3660 covers termite management systems for buildings.
It must be installed before the pour; afterwards the penetration is sealed around whatever is there.
Collars are one part of a system, alongside perimeter treatment and inspection zones.
We recorded collars not installed on more than one Oran Park penetration.
More about Oran Park
- Building a new home in Oran Park NSW
- Buying a home in Oran Park NSW
- Growth and development in Oran Park NSW
- Certifiers, council and building disputes in Oran Park NSW
- Ground conditions and slabs in Oran Park NSW
- Common building defects in Oran Park NSW
- Insulation at lock-up in Oran Park NSW
Written by our local inspection team from work carried out in Oran Park. Licensed building practitioners.